1. Installation of aeration or blowback device.
Setting an aeration device at the grid can effectively prevent the grid from clogging so that once there is suspended sludge or filler at the grid, it will also be blown away to avoid its clogging.
In the mixed liquid back to set up blowback device is also an effective measure to prevent the grid clogging. In actual operation, the grid at the return of mixed liquid is often clogged.
Of course, if the design of the initial stage did not take into account the design of the blowback device, you can manually blowback, although each time the clogging has to manually blowback, bringing a certain amount of workload to the staff, and each time to dismantle the pump to install the pump is also very inconvenient, but the problem can be effectively solved. Setting up automatic cleaning device: A regular automatic cleaning device can also avoid the grille clogging.
2. Add mesh fence to intercept.
The filler will be covered with the grid as a whole, and even if the blockage will not cause the loss of filler, there is no problem of filler entering the pipeline to cause pipeline blockage, the system recovery will also be quickly recovered, as long as the blocked grill is cleared, the system can operate normally.
3. Add a liquid level meter.
Installation of a high liquid level meter in each pool, a grille blockage is bound to rise in water level, when the water level rises to a high level when the system stops feeding water, which can prevent the water level from overflowing, loss of filler so that the pipeline is blocked. In this way, after manually cleaning the blocked grating, the system can immediately return to normal operation.